This board won?t turn on at all .
had no liquid damage , no sound when plug the charger .
i get 3.3v on pp3v3 G3h
8.59v PPBUS G3H
3.3v pp3v3_s5
8.59v PPBUS S5 HS COMPUTING ISNS
when plugged to charger cpu stay cold
Is that part of the horrible design on these screen !!
no cracks or physical damage , screen goes totally black
if bend more then 90 degrees.
seen this on so many of these models !!
This board has no liquid damage at all .
the PPBUS-G3H was 0 v and shorting to ground .
i found that U7210 was very hot when i injected 5v .
took the U7210 then no more short At PPBUS.
solderd new U7210 now I get 13.05 v at PPBUS with charger only
and 13.01 with battery.
pp3v3_g3h 3.410
no...
there no liquid damage involved or any physical damage .
thr fan spin qurater spin then stop then again .
got green light on the charger , PP3V42 is 3.49v PPBUS is 12.60 v ?
I am very happy because LOUIS got the Forums working !!!
Had liquid damage , after cleaning the board there was no
backlight , I did reflow the LP8550 then worked for 2 days
then again no backlight , I replaced for new LP8550 but still no backlight , thought I might did bad soldering joint...
Has liquid damage , after cleaning it will turn on , light comes
on the charger , then light on the charger disappear after few 20-30 seconds . The charger goes to protection status , I must
unplug it from wall to work again .
i replaced I/o board and the flex cable , checked J9500 all pins...
shows battery replace now
replaced 3 new batteries and the battery cable still same thing
replaced the main board still same ?
is it touchpad related !!
very weird
macbook had liquid spill .
turns on only keyboard not working , touchpad is fine .
i replaced the full assembly keyboard with new keyboard cable
but keyboard still not responding .
i have the same board which working one , installed it
to the new top case keyboard but no keyboard working
which...
this 820-2849 from 2010 17 inch shows only keyboard and mouse
image on the screen .
disconnect everything from the board not solving the issue .
tried new keyboard , new drive , nothing works .
please check images .
This had liquid damage , was cleaned in ULSONIC , get green light
on the charger , PPBUS is 0.1-0.3 v , no short on PPPBUS.
when injecting 8.6v to PPBUS the board does turn on and
fan spin .
assume missing PPBUS, all PPBUS looks clean .
This board works fine with 85w charger and charge fine but when switch to
45w charger show light on the charger then go off .
tried different 45 w but same result .
assuming there something wrong with PP3v42-g3h ?
I get green light on the charger pp3v42 is 3.42 v
ppbusg3h 8.6 v
PPBUS S5 computing isns 8.6 v
PPBUS S5 other isns 8.6 v
PP5v S5 5v
PP3V3 S5 3.3v
unplugged the I/o cable still nothing
no fan spin !
No liquid damage ,working with external monitor fine .
customer tried to replace broken screen but no backlight with any working screen , tested 4 of them with new lcd cables
F7700 is fine 0 ohm no short to the ground .
maybe the LVDS .
This was liquid damage, after cleaning in ULSC the DDCIN was missing due short on C7190 which blow D7105 , replaced C7190 and D7105, now getting 20v , still no power, checked all other 3v42 PPBUS all there, but not getting any voltage on PP3V3_S5 and PPV5_S5 .
no short to these lines or any...
Hi there
on the 820-2915 the PP3V42 is present 3.4V the PPBUS_3GH is 1.3 v.
i found there short to the ground ,by removing the C7340 C7341, the short is gone , but as soon i replaced them few times now , the short is back. these 2 capas boiling hot , what could causing the short now ?
Hi there
As it is known issue with MacBook Pro 15" 2011 bad MCP OR what known as AMD GPU
The system wont pass the loading bar, wont post , tested with different drives but nothing .
After replacing the GPU with new chip (which we done hundreds of times for the past years ) system worked just...