For $29/mo, we provide access to advanced level technicians who will answer your questions on any Macbook board related matter to the best of their knowledge promptly & walk you through how to solve your problem so you can deliver a working board to your customer.
Hi,
I replaced D7105 that diode was problem after replacing device is charging and working normal on battery.
Device works normal and out of the blue screen starts to flicker sometimes, I reflowed connector inside the screen and I didn't get that problem again for now, I tried to post the...
I replaced what you said, q7130 didnt blow yet and when it blows device will work, now its short circuit somewhere but nothing even close to 0 ohm, what to do next i replaced u7100 and q7130 tested all leads all over chip is 0.300 or more no short
I will post measurments on board, q7155 was shorted, after swapping it device is telling to plug the charger for the first time.
On
1
PPVBAT_G3H_CHGR_R - steady 20 V
5
PPVBAT_G3H_CONN - withouth battery no reading
Reading on board when q7130 off board
2
PPDCIN_G3H_CHGR 0.590
7...
CHGR_Phase and PPDCIN_G3H_CHGR is shorted on q7130 on all 3 that i have
2
PPDCIN_G3H_CHGR when i measure with q7130 removed voltage drop is 0.574
7
CHGR_PHASE voltage drope wthout q7130 is 0.410
I replaced u7100 and q7155 and removed q7130, didn't turn on board yet bcs i'm not sure if q7130...