Search results

  1. G

    820-3437-B PP3V3_S5 shorted

    Actually PP3V3_S5 is shorted but present, so could it heat with the MagSafe only ? I don't have any lab supply yet and I tried with the MagSafe and an IR camera, the only hot point is under PCH (or the other side of the board I don't know). CPU heatsink was already removed.
  2. G

    820-3437-B PP3V3_S5 shorted

    I never plugged the board since I removed SMC and U7501. The short is 22ohms. When I lift L7560 the short is on PIN 2 and when U7501 lift up the short is only on PIN17, it looks like the short is on PP3V3_S5_REG_R. When I remove components I put them back in place after I checked the short still...
  3. G

    820-3437-B PP3V3_S5 shorted

    Hello there ! I have a 3437-B from a MBA 2013. At the beginning I had no light on charger and no fan spin, no more historic. I found corrosion on PP3V42_G3H supply, I replaced the bad components and still no light on charger. I tried reflow SMC without success, and I finally had a light on...
  4. G

    820-4924-A - Work fine but no image on LCD

    Every components are present. Diode mode on these caps gives me 0.267. Does someone have a good 820-4924 to confirm me these values ? Also, I measured EDP_BKLT_PSR_EN and EDP_PANEL_PWR_OR_PSR_EN on U8330, I have both 3.3V. I ordered a new assembly, I'll give you some news as soon as it arrive...
  5. G

    820-4924-A - Work fine but no image on LCD

    Ok so it's a good news if 40V is normal, all my power rails seems to be fine on the LCD connector. I'll try an other assembly as soon as I find an other one. When you say "check all C832x", you mean check for a short on the pins or there is an other way to check a capacitor ? All traces between...
  6. G

    820-4924-A - Work fine but no image on LCD

    Hello, I have a A1502 with a 820-4924-A that is working well when plugged in Display Port on external display. With internal display plugged in I have no image on it (but still on external display). The Apple Logo on the back cover is ON when the OS boot is over and I have PPVOUT_S0_LCDBKLT =...
  7. G

    820-00281-A Critical Update and Touchbar doesn't work

    Understand, I'll check every signal with touchbar connected. And what do you think about the voltage of SOC_PCH_DBELL_L = 1,6V ?
  8. G

    820-00165-a

    Hello ! i had same problem with a 820-00165-A, I cleaned ME Region and it worked fine.
  9. G

    820-00281-A Critical Update and Touchbar doesn't work

    "U4406 PIN 4 DFR_DISP_SMC_RST_L = 3,42V There is an error; please post accurate information." My bad I mean PIN 1 DFR_DISP_SMC_RST_L = 3,42V "Check lid, reset and detect signals at J4402." J4402 - PIN 2 DFR_TOUCH_LID = 1,76 - PIN 1 TOUCH_PANEL_DETECT = 0,05 - PIN 15 DFR_CLKIN_RESET_L = 0,09 -...
  10. G

    820-00281-A Critical Update and Touchbar doesn't work

    Boot fine in safe mode but touchbar and backlight keyboard doesn't work (I assume it's normal bc of safe mode). With normal boot the macbook ask me for a critical uptade, tried with wifi, wired cable and I also tried what this guy say on a forum...