I purchased this board, came fully functional aside from not recognizing battery. Looks clean, no evidence of liquid.
U7000
Pin 11 3.4v stable
Pin 10 SMBUS_SMC_BSA_SDA moves between 3.4v - 0.15v
R5280 2K
R5281 2k
SMBUS_SMC_BSA_SDA is stable at 3.4v on pin 1 of R5280 while pin 2...
History is a guess aside from what I see which is lack of corrosion, no real discoloration of any probe points. Trace amounts of fruit punch(?) around the base of C7119 and C7120; highly likely was cleaned before falling into my lap. it arrived naked in a lot which contained several broken...
Fan spins for a few seconds during which all S0 rails turn on but fall off after stopping. I've tried changing U2700, checked u7000 current sense's. What should I be looking for at this point in terms of ****_PWRGD signals etc. aside from the S0_Mains verified?
Questions:
1) When moving...
I was borrowing an SPI chip from one board for use in another (yes idiotic to begin with) but popcorn'ed it prior to a successful dump. Does anyone have a .bin for a 820-3024 1.6ghz 4gb?
Thanks from the past.
Just power cycles continually until U6100 area is heated, afterwards it will turn on, chime, present image etc. Is it possible I over heated the new SPI chip and is now failing as well? There isn't anything on the other side of the board that's being heated as a result of U6100 targeting as far...
This board started out with quarter fan spin. I noticed that one of the SPI_MLB_CS_L resistors was missing and when replaced the board turned on but a day or so later the quarter fan was back.
When heat was applied to the U6100 area the board would turn on so I dumped the rom thinking the chip...
After replacing the garbage poly-tantalum easter-egged cap this board is stable, however...
(2) errors in ASD OS... (running on a naked logic board FYI)
*TsOP temp. (Palm rest test #1)
"SMC could not initialize this sensor" - I assume trips because the palm rest is absent...