    I have an A2141 that negotiates 20V, pulls 3 amps when off and 4 amps when I press the power button. Fans spin but the macbook does not...
  • 2informaticos
    2informaticos replied to the thread A2681 820-02872.
    If you still see something on the screen (even dimmed), try to share the disk for data recovery through USBC.
  • K
    kashitozu replied to the thread A2681 820-02872.
    yeah same thing in internal screen. i have say the internal keyboard not working.
  • airambulance.india
    airambulance.india updated their status.
    Swift ✈️ Reliable 🕒 Life-Saving ❤️‍🩹 Premium Air Ambulance Services in Patna, delivering critical medical transfers when every second...
  • airrescuers12
    airrescuers12 updated their status.
    Critical Care Air Ambulance Connectivity Between Kerala and Mumbai #EmergencyAirSupport #KeralaRescue #AirAmbulance #LifeSaver...
  • E
    evilsmith229 commented on kayanvent's profile post.
    PKHeX is really convenient for Pokémon fans who like customizing their game experience, especially with its support for both online and...
  • 2informaticos
    2informaticos commented on dexbdv's profile post.
    For testing purpose, you can make a bypass over Q3100, or Q3200; depends which channel doesn't work properly. However, you MUST use a...
  • D
    dexbdv left a message on 2informaticos's profile.
    У меня были платы 00840/00875, на которых я получал выходное напряжение 1,1 В LDO только от одного CD3215. Иногда я проделывал трюк с...
  • airambulance.india
    airambulance.india updated their status.
    Wings of Hope in Jorhat! Meet the fearless Air Ambulance Services in Jorhat, delivering critical care and rapid response when time is...
  • airrescuers12
    airrescuers12 updated their status.
    From remote mountain regions to advanced medical care, air ambulance services in Himachal Pradesh ensure swift and safe patient...
  • 2informaticos
    Still low reading (0.083) at PPVDD_DISP_S1? If yes, remove L8280/1 and R820C. If still low, bad CPU, or some filter capacitor (less...
  • R
    Do you have any advice or an idea of where to start to check?
  • R
    Like last week I fixed one A1990, which has all CD3217 faulty. I replace then randomly with china ic and from a donor board. I had to...
  • R
    I read before that if replace at least the master with another master, then we can replace the second IC with any other new or from any...