Search results

  1. D

    SOLVED A2338 820-0020 left shift doesn't work

    So left shift is absolutely kbd_sense_x10. I had a broken trace from ut102 to pin 2 of rt140. It had corrosion i couldn't see at all. Thanks for the help.
  2. D

    820-02100 a2485 no power

    Yes exact postion from a2442 board. I read about the firmware thing. Yes i will do. Also so about the port not working one side what are the chances that the cd3217 chip i used is causing that.
  3. D

    820-02100 a2485 no power

    Hi, hope you are having a good day. So this board is heavy liquid damage. Ppbus_aon was shorted due to ur760 and ug800 and ug400 was blown. And up800 ( i just removed it as waiting for more of them) I took off ur760 Replaced ug400( donor board a2442 but not sure if its good) ug800. So no...
  4. D

    SOLVED A2338 820-0020 left shift doesn't work

    Hey so quick update on this, still waiting for a damaged keyboard to rip apart but in the meantime i think i have found something kbd_sense_x10 has a weird diode mode reading. Its 0.800 verus a good board and open data it should he 0.600 ish. So i replaced dzt204(again) and ut102 and nothing...
  5. D

    820-02098 a2442 no backlight

    Took up800 put red probe on pin 7 and black on 32 and diode mode result is 0.06 so chip is now bad but this was a good chip. I wonder if something in the circut shorted it or was it when i reballed it. In any case thank you for the help so far, will revist when i have more chips and will post...
  6. D

    820-02098 a2442 no backlight

    Check on cp810 as i have done that and its ol or are you saying to check on the chip directly? Damn that was a chip off a board with working backlight. I wonder what happened. As always really appreciate your help. I will check the chip to be sure but if it is bad it will have to sit awhile as i...
  7. D

    820-02098 a2442 no backlight

    So the initial reading of 0.06 was with it on and then when i had taken it off the reading went to 0.07 and started to drop back down. Then i put the cap back on. Also the ohm reading on luxe_c_vdd is 45 with one probe on ground
  8. D

    820-02098 a2442 no backlight

    Alright so i have replaced everything that had even the slightest bit of liquid that had to do with lcd and saw no broken traces so then i started to look at voltage and see if anything is missing and in that process i have come across luxe c vdd has 0.0 v and when i did diode mode it shows up...
  9. D

    820-02098 a2442 no backlight

    I see. Well will replace as much as possible then and report back. Also thank you very much for always getting back. Anything in particular i should focus or look at.
  10. D

    820-02098 a2442 no backlight

    Yes. The result is no backlight
  11. D

    820-02098 a2442 no backlight

    Oh this is a fun one. Liquid damaged. Initially didnt power on, thats fixed. Here what i have done so far, anything that looked severly liquid damaged i just replaced. Here is the list - Up800 Cp821 Rp801 Rp802 I dont understand this new backlight circut well as i am still learning to...
  12. D

    820-02098 a2442 5v

    Its all good. I figured it out. But thank you
  13. D

    820-02098 a2442 5v

    Not sure if i need to make another post for this but I have another board that came in as well. It goes to 19v and about 0.21a and then the meter reboots. What weird is that it does it slowly like 5v then 15v and then 19v or it will have like 7v and 9v including in that process. Not sure if that...
  14. D

    820-02098 a2442 5v

    Ah thats why the pinout says nfc, wait for starters i really appreciate your time for telling me that, i just realized i could have google the chip number. Well wish me luck for this machine
  15. D

    820-02098 a2442 5v

    Fair enough, i have been removing chips with no change, so will continue to do as i would have to remove alot of these chips and replace them due to liquid damage. Do you know the purpose of u5000, it just says secure element but i would like to know its purpose
  16. D

    820-02098 a2442 5v

    Back again. This machine is extremely liquid damaged and has me confused as i am still new to it. Board got 5v and 0.3a These are the lines that are shorted or low diode mode reading Pp3v8_aon 0.120 Originally was shorted to ground but took off ur630 and thats the new reading...
  17. D

    SOLVED A2338 820-0020 left shift doesn't work

    So i reinstalled the os just to be on the safe side and again still no left shift. I am at a loss. Idk what to try next.
  18. D

    A2337 820-02016 ppbus_aon low

    Alright so i removed f5200 again and wanted to check if voltage would stabilize. It did not however it started to cycle from 1-2v. When to check q5230/40 again. Saw in diode mode q5230 pin 8 was 0.038. So i took it off. Gave the machine power again and checked pin 1 of f5200 and it was 1.8v and...
  19. D

    A2337 820-02016 ppbus_aon low

    PPBUS_AON just cycles from 11.73v to 10.34v and in the cycles goes down to zero. The cycle is continuous and at no point stable for one second except when it goes to zero. 3v8_aon is not present