Search results

  1. kevinklinkmuller

    820-00138 turns on, battery error symbol, then turns off. Works fine in SMC bypass

    before and after removal the 3v42 rails are quite low. 10 ohms short to ground, so must be a cap, should i inject voltage and see what heats?
  2. kevinklinkmuller

    820-00138 turns on, battery error symbol, then turns off. Works fine in SMC bypass

    U7100 pin 9 - 0.030v pin 15 - 0.065v As i was measuring this, the R7020 blew up. I think i might've plugged in the charger wrong because there's no green light. have replaced it with another resister with the same marking "470" but still no green light. What did i do :(
  3. kevinklinkmuller

    820-00138 turns on, battery error symbol, then turns off. Works fine in SMC bypass

    820-00138 turns on, battery error symbol, then turns off. Works fine in SMC bypass. So sensor issue? How do I sort sensor issue.
  4. kevinklinkmuller

    820-00165 green light, no fan spin

    so been testing this machine and it magically worked after ultra sonic. customer is happy. SOLVED
  5. kevinklinkmuller

    820-3476 green light, no boot. Weird 5V rail behaviour

    thank you,tried it on this one and nothing
  6. kevinklinkmuller

    820-00165 green light, no fan spin

    SMC bypass works woo!!!! No backlight though. So it's a sensor issue? no pulse on l7520 which is what i think you meant ppbus is 8.58 well i thought it didnt charge the battery but after the ultrasonic it does. also it's showing the batt symbol and fan spin without bypass when battery is...
  7. kevinklinkmuller

    820-3476 green light, no boot. Weird 5V rail behaviour

    ok, have tried smc bypass mode, doesn't work
  8. kevinklinkmuller

    820-3476 green light, no boot. Weird 5V rail behaviour

    is SMC bypass where i have to run a wire to ground repeatedly? How do I do that? thanks!
  9. kevinklinkmuller

    820-00165 green light, no fan spin

    Hi there water damaged 820-00165 here. All S5 rails present. Thermal cam shows isl6259 has a tiny bit of heat. but i suppose it's expected I'm about to put it in the ultrasonic cleaner
  10. kevinklinkmuller

    820-3476 green light, no boot. Weird 5V rail behaviour

    PPbus is 12.58v U7501 pin 23 is 12.58 pin 13 is pulsing between 0 and 2v pin 22 is 3.3v pin 29 is is sometimes 0, 2.5 and 5 pin 12 pulsing between 0 and 3.3 pin 21 pulsing between 0 and 3.4 pin 4 0v 3v42 is stable at 3.4v
  11. kevinklinkmuller

    820-3476 green light, no boot. Weird 5V rail behaviour

    Have an 820-3476 with green light. I think it had liquid damage initially but someone else has already messed with the board so i can't really tell It has green light. Have started going down the power rail list. everything looks normal and i've stopped at the 5v rails because they are acting...
  12. kevinklinkmuller

    820-00165 green light, no fan spin

    so oscilloscope is necessary now?
  13. kevinklinkmuller

    820-00165 green light, no fan spin

    PM_PWRBTN_L reacts and drops from 3.4v to 0.3v. is that close enough?
  14. kevinklinkmuller

    820-00165 green light, no fan spin

    I think i have good news! i soldered a bigger wire to smc_onoff, and PM_SLP_S5_L and PM_SLP_S4_L are consistently responding to rapid triggering s5 goes to 0.002 and s4 goes to 0.03 consistently. However PM_SLP_S3_L is not responding at all. it's dead
  15. kevinklinkmuller

    820-00165 green light, no fan spin

    shit, the PCH is the CPU??
  16. kevinklinkmuller

    820-00165 green light, no fan spin

    so i basically tested for continuity on SPI_CS0_L and it's ok :(
  17. kevinklinkmuller

    820-00165 green light, no fan spin